Everyone will recognise the simple Dinkler-Thor differential axis vectoring setup here. The problem is that I can’t rotate past 27 degrees without the inverter fluctuating and losing lock. Can anyone spot my mistake? I feel like I’m missing something really easy.

  • DickFiasco@sh.itjust.works
    link
    fedilink
    English
    arrow-up
    3
    ·
    12 days ago

    The whiteboard in the background shows an inverter configured for passive resonant signal filtering, but it looks like you have the inverter wired through a pre-amp matrix, which would default to active filtering. This will certainly cause instabilities beyond 27 degrees or so.

    • Naich@lemmings.worldOP
      link
      fedilink
      English
      arrow-up
      3
      ·
      12 days ago

      Yes! I think that’s it! The 63rd wire from the right is plainly going to the matrix. Thanks.